系列選型兩位兩通防爆電磁閥ode,ODE技術(shù)特性 The danger areas are the places in the system where a dangerous atmosphere could be created during normal operation or because of breakdowns. In Italy the classification of danger areas is regulated by the CEI 60-2 standard, some notes on which are given as follows: DANGEROUS ATMOSPHERE 系列選型兩位兩通防爆電磁閥ode,ODE技術(shù)特性


系列選型兩位兩通防爆電磁閥ode,ODE技術(shù)特性  的詳細介紹

系列選型兩位兩通防爆電磁閥ode,ODE技術(shù)特性


The danger areas are the places in the system where a dangerous atmosphere could be created during normal
operation or because of breakdowns. In Italy the classification of danger areas is regulated by the CEI 60-2 
standard, some notes on which are given as follows:
DANGEROUS ATMOSPHERE
A dangerous atmosphere is an atmosphere formed, or reasonably liable to be formed, by the mixing with air, at
atmospheric conditions, of inflammable substances in the form of gas, vapours, smoke or powders in such 
proportions that a thermal phenomenon (excessive temperature, electric arc or spark) may cause them to 
explode.
DANGEROUS PLACE
Dangerous places are subdivided into the following four classes (in function of the substances present):
- C0 (CLASS 0 places): places containing explosive substances.
which may occur. The temperatures are referred to a room temperature of 40°C.
N.B.: the term "billion" in Italy, Germany and Britain has the meaning of 10 whereas in
U.S.A. and France it has the meaning of 10 . Therefore, if this term should be used, it is advisable to request an clear explanation of its meaning so as to avoid mistakes.
sometimes the power absorbed by coils is expressed in volt-amperes (VA). This measurement
unit does not have a fixed correspondence with the S. I. measurement unit (Watt). This non-correspondence is because of the voltage-current phase displacement which, when the coil is energized
with alternating current, varies as the coil and the valve on which it is mounted vary. 
An APPROXIMATE value for VA-Watt correspondence is 0.6: 1 VA = 0.6 Watts
- episodic or for short periods of time (ZONE 2)
- present for periods of less than 0,01 hour a year. (ZONE R)
The safety required depends on the CLASS combined with the ZONE rating.
For CLASS 1 (C1) equipment, the standards provide for a further classification based on the installation place
and the gas type that may be present. Therefore, there are 2 subgroups:
GROUP I - Equipment to be used in mines
- C1 (CLASS 1 places): places containing inflammable substances in the form of gas or vapours in minimum
quantities indicated by the standard.
- C2 (CLASS 2 places): places containing inflammable powders (E-electric conductors; NE-non-electric 
conductors).
- C3 (CLASS 3 places): places containing inflammable substances in quantities which are lower than the 
minimum indicated for class 1.
By the legislative provisions, in dangerous atmospheres, in Italy only equipment conforming to the "EEx"
European standards can be used which have been certified by an authorized laboratory and which bear the 
distinctive community mark.
As in some countries there are local protection methods which are not recognized by CENELEC, some of these
are listed as follows:
- (CEI 79-15) "N" non-incendiary protection method for zone 2 (Netherlands and United Kingdom)
- "H" hermetic protection method (Netherlands)
- "S" protection method (Netherlands and Germany)
- ICS-6 A NSI/NEMA 7.9 Standard (U.S.A.)
PARAMETERS FOR THE CHOICE OF THE PROTECTION METHOD
The choice of protection method depends on the place where the equipment is to be installed (class and zone)
and subsequently on the type of atmosphere present.
DANGEROUS ZONES
A zone where the presence of a dangerous atmosphere is possible. There are four types of dangerous zone
depending on the fact that the dangerous atmosphere is:
- permanent or for long periods of time (ZONE 0)
- intermittent in normal service (ZONE 1)
TEMPERATURE CLASSES
For all GROUP II equipment, the standards also provide a classification based on the maximum surface 
temperature that the same equipment can reach both during normal operation and because of any breakdowns
GROUP II - Equipment for surface installation.
GROUP II is further subdivided based on the atmosphere to which the equipment is destined. For protection
modes "d" and "i", the standards define three subgroups (A-B-C) which identify the gases with which the 
equipment comes into contact.

系列選型兩位兩通防爆電磁閥ode,ODE技術(shù)特性

Copyright@ 2003-2024  上海乾拓貿易有限公司版權所有     

Copyright@2003-2018 上海乾拓貿易有限公司版權所有 電話(huà):021-39529830/39-8005  021-39529831/29-8002 傳真:021-39529839 

地址:上海嘉定嘉涌路99弄6號713 郵編:201812  易展提供技術(shù)支持  滬ICP備09006758號-20    網(wǎng)站管理入口

         滬ICP備09006758號-20   

滬公網(wǎng)安備 31011402005010號

點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 成人99精品久久毛片A片小说,浪漫樱花动漫在线观看免费,男s严厉调教女m小说,驯服人妻HD中字日本
开封市| 佳木斯市| 西宁市| 防城港市| 峡江县| 富顺县| 孟连| 梨树县| 鄂尔多斯市| 遂川县| 南阳市| 冕宁县| 凌云县| 越西县| 盐亭县| 米林县| 苗栗县| 且末县| 武宣县| 祁阳县| 茂名市| 南京市| 铁岭县| 聂拉木县| 泾源县| 苏尼特右旗| 田林县| 诏安县| 临湘市| 静海县| 萍乡市| 南岸区| 桦甸市| 多伦县| 铁力市| 新蔡县| 新安县| 马尔康县| 托里县| 山阴县| 彩票| http://www.010gt.com http://www.nyw6.com http://www.88dxy.com http://www.kzcs26.com http://www.mm272.com http://www.kkyy18.com